How-To GUIDE

How to Assign & Install Sensors

If you haven’t set up locations for sensor assignment yet, please refer to the guide “How to Create and Edit Rooms and Zones”.

AROYA hub mounted on a white wall with power and blue Ethernet cables connected and green status lights illuminated.

Assign sensors in the web app

AROYA web app showing the Setup gear icon and the unassigned sensor table with a device serial number checkbox selected.
  1. Click the Gear Icon for Setup
  2. Select your sensor to assign by looking for the serial number matching the serial of your device’s label
  3. Click “Assign Selected”
Assign Sensor dialog in the AROYA web app with Room and Zone dropdown menus selected and the "Save" button highlighted.
  1. Choose Room and Zone to assign to
  2. Click “Save”

Assign sensors in the mobile app

AROYA mobile app menu showing the “Devices” option.
  1. In the menu, click “Devices”
AROYA mobile app Devices screen showing the list of devices and the “QR Code” button.
  1. Click on the device you’d like to assign

Tip: Have many devices? Click on the “QR Code” button and scan the device serial label to quickly bring up your device

AROYA mobile app device screen with Room and Zone selectors and the “Save” button.
  1. Choose Room and Zone to assign to
  2. Click “Save”

Install sensors

Climate stations

Diagram of the AROYA H421 Climate Station suspended from an overhead structure by a rope pulley and carabiners, with an Ethernet cable running to a PoE wall plug.

Use the included pulley to suspend the Climate Station in a central location above your plants. For optimal signal strength, place sensor within 30 feet of any other AROYA device.

  1. Hook the carabiner on the pulley to the Climate Station
  2. Hook the other carabiner to the ceiling or structure above plants
  3. Adjust the height of Climate Station as needed by adjusting the rope length using the pulley
  4. Connect the Climate Station to power using the provided ethernet cable and Power over Ethernet (PoE) wall plug
Diagram of the AROYA H411 Climate Station suspended from an overhead structure by a rope pulley and carabiners, with an Ethernet cable running to a PoE wall plug.

Tip: Power your Climate Station directly from your PoE supporting switch/router if preferable

Substrate sensors

It’s recommended to use the AROYA alignment tool when installing substrate sensors. This will allow for consistent installation of sensors and provide better data quality.

  1. Align the alignment tool with the bottom of the substrate
  2. Push the sensor into the substrate through one of the slots on the alignment tool
  3. Slide the alignment tool out and push the sensor in the rest of the way
Alignment tool being slid away from the grow block while the AROYA substrate sensor is pushed completely flush against the substrate.

Still have questions?

We can help! Reach out to our support team.

Contact support