Elements
kitchen sink

A long page of components and put together elements that can be used on Addium Webflow projects.

Eyebrow text

Heading text that can be multiline

Button text
alt="Experience next-level precision in substrate data with TEROS ONE. Advanced technology for unparalleled electrical conductivity, temperature, and volumetric water content readings. Ideal for cannabis cultivation, offering reliable data comparisons and seamless integration with AROYA platform."

Grow header

AI-powered precision substrate irrigation systems that help you harvest your best ever with less effort.

Call to action

One sensor. Three metrics. No weaknesses. TEROS™ ONE’s new design completely reimagines how substrate data is collected, giving cultivators precise and accurate readings in zones other sensors simply can’t measure at all.

Grow better and conserve resources with AI-powered substrate irrigation

Explore AROYA

Measure, manage, and optimize water’s impact in low-moisture applications

Explore AQUALAB

Solving business problems and saving the world — at the same time.

Learn more about our mission and impact.

About Addium

Our latest innovation

Truly autonomous irrigation, powered by AI.

For decades, companies have promised “smart” or “automatic” or even “AI-powered” irrigation. None have delivered anything that really works. Until now.

Find out more
Screen view of IRRIGAIT software for AROYA showing scheduled irrigation events across multiple grow rooms

No schedule.
No set points.
No programming.

AROYA’s intelligent irrigation integrates with controls, using advanced AI decision-making to automatically steer your crops to the goal you’ve set. You don’t build, maintain, or refine an irrigation schedule – because there isn’t one. No set points, either. No constant tweaking. Just immediate, intelligent decisions.

Electrical conductivity
(dielectric pore water EC)

🪣

Volumetric water content

🌡️

Temperature

Comparison charts showing TEROS ONE sensors with linear accuracy, previous TEROS sensors with nonlinear results, and knockoff sensors with inconsistent curves
No plug, just play. There’s just one piece to the TEROS ONE – no ethernet cables, no internet setup, no plugs. Simply use the AROYA app to scan the sticker on the TEROS, and it links up seamlessly.

Repeatable data, grow after grow. The included TEROS™ ONE alignment tool helps you place your sensor perfectly every time. Works in soil, soilless mixes, coco, and rockwool right out of the box without the need for user calibration.

SOZO

“AROYA is a better gardener than me, I'll be the first to say that … It's literally the best employee that we have here.”

Read the Sozo story

Modal

Duplicate "card-w" to create a new modal popup

On Click

Open Modal

How to:

  1. Add the combo class named demo-request to the modal element.
  2. Change the Display setting of the modal element to Flex to make it visible for editing. Remember to change it back to None when you are finished.
  3. Edit the content within the modal-scroll-content-w element.
  4. Copy the button element that includes attributes such as page scroll lock scroll="disable" and scroll="enable" to deploy the modal.
  5. Paste the modal element into the Modals Container component.

Get the latest from Addium in your inbox.

Join our mailing list to get regular updates about new products, initiatives, and recommendations.

Thank you! Your submission has been received!
Oops! Something went wrong while submitting the form.

Specifications

Relative Dielectric Permittivity

Frequency:   

70 MHz

 

Range: 

1 to 80 (tested)

 

Resolution: 

0.1

 

Accuracy:

± 3 % (for 0 < EC < 15 dS/m)

Electrical Conductivity

Frequency:

zero (estimated from values measured at 70 MHz)

 

Range:

0 to 20 dS/m (tested)

 

Resolution:

0.001 dS/m

 

Accuracy:

± 2 % or ± 0.05 dS/m (for 0 < EC < 20 dS/m)

 

Temperature

Range:

-40 to +60 °C


Resolution:

0.1 °C


Accuracy:

± 0.3 °C

Volumetric Water Content *

Range:

0 to full saturation (porosity for RW » 95 %)


Resolution: 

0.001 m3 / m3


Accuracy:

± 0.05 m3 / m3

Electrical Conductivity of the Water Phase (ECpw) *

Range:

0 to 15 dS/m (tested)


Resolution: 

0.001 dS/m


Accuracy:

± 5 % or ± 0.1 dS/m (for 0 < EC < 15 dS/m and 0.15 < VWC < saturation)

Other

Material:

ASA Plastic

Measurement Interval:

3 minutes

Power:

Embedded Lithium Battery, 5+ year life.

* While they are strictly valid for Rockwool, the estimates above reasonably apply to all inert materials with very high porosity, such as peat moss or organic substrates made from coco’s fibers.